Features & Benefits
Lobeline Rotary Lobe Pump is designed with features that provide maximum uptime
The AIR GAP DIFFERENCE
Minimum Down Time. Optimum Reliability.
The Lobeline Rotary Lobe Pump features a maintenance-friendly front pullout design that allows a complete in-place wet end rebuild without removing the pump from the baseplate, disconnecting suction or discharge piping, or requiring realignment. This innovative design minimizes downtime, reduces maintenance costs, and returns your system to service faster.
- Hinged Front Cover
- Cartridge Mechanical Seals
- Rear Wear Plates
- Radial Wear Plates
- Straight Rotor Design
- Taper Locking Assemblies
- Rotor Caps with O-Rings
Maintenance Friendly Front Pullout Design Wet End Rebuild
A design that facilitates complete in place wet end rebuild without removing the pump from the baseplate, disconnect suction and discharge piping, or realignment
Rotor Case
Gear Case
Hinged Front Cover
Mechanical seals cartridge type with shaft sleeve
Rear wear plates, upper and lower
Radial wear plates, upper and lower
Rotors – Straight design to facilitate removal of one rotor at a time without special tools.
Taper locking assemblies to simplify removal and reinstallation of the rotors.
Rotor cap with "O" rings
A.
Rotor Case
Gear Case
Hinged Front Cover
Mechanical Seals Cartridge Type with Shaft Sleeve
Rear Wear Plates, Upper and Lower
Radial Wear Plates, Upper and Lower
Rotors – Straight Design
Taper Locking Assemblies
Rotor Cap with O-Rings
Rotor Case
Gear Case
Optional Sealed Gearbox Design: In addition to the front bearing isolator, the timing port plate can be fitted with a labyrinth seal along with sealed expansion caps in place of the traditional vents. These optional features (not shown) allow the gearbox to be fully immersed in flood conditions, or to function in extremely humid environments.
Visible Air Gap Design for true and foolproof separation of the rotor case A from the Gear case
Optional Radial Wearplates: Upper and lower wear plates patented design eliminate casing replacement. Retained via a series of externally-sealed fasteners which allow pump to be serviced in place.
Taper Locking Assemblies: Used on rotors and gears to simplify removal and refitting.
Timing Port Plate: Located at the drive end, it permits easy entry to the taper locking assembly (eliminating the need to remove the gearcase cover), allowing pump to be re-timed in the event of a blockage within the pump casing. No more worries about oil drain-down!
Different Sealing Options, Cartridge Type Front Pullout with Shaft Protection Sleeves.
Labyrinth Bearing Isolator: Stainless steel construction eliminates ingress of liquid into the gearbox. Double-lip oil seal retains oil; grease nipple allows grease input to act as barrier within the labyrinth. Functions in static or running state.
Optional Rear Wearplates: Upper and lower plates to protect casing. Retained via a series of externally-sealed fasteners.
Front-Loading Seal Area: Allows the hardened shaft sleeves or mechanical seals to be removed cartridge style through the front of the pump—without removal of the casing.
Hinged Front Cover
Straight Lobe Design benefits: Low NPSH r, Superior Performance, better non compressible solids handling capability.
Heavy Duty Duplex Roller bearings per load point for longer bearing life.
Upper Oil Chamber to ensure lubrication of the upper bearings at low speed
Lower Oil Chamber for lower bearings and continued timing gears lubrication
Heavy Duty AGMA quality timing gear accessible for timing without having to drain the gear case.
Dual Oil Breathers / Oil Filler Cap with Sealed Expansion to prevent moisture and dirt from entering the gear case
OPTIONAL SEALED GEARBOX DESIGN
In addition to the front bearing isolator, the timing port plate can be fitted with a labyrinth seal along with sealed expansion caps in place of the traditional vents. These optional features (not shown) allow the gearbox to be fully immersed in flood conditions, or to function in extremely humid environments.
Dual Oil Breathers / Oil Filler Cap with Sealed Expansion to prevent moisture and dirt from entering the gear case
Visible Air Gap Design for true and foolproof separation of the rotor case A from the Gear case
Heavy Duty Duplex Roller bearings per load point for longer bearing life.
Gear Case
OPTIONAL RADIAL WEARPLATES
Upper and lower wear plates patented design eliminate casing replacement. Retained via a series of externally-sealed fasteners which allow pump to be serviced in place.
Rotor Case
Straight Lobe Design benefits
Low NPSH r, Superior Performance, better non compressible solids handling capability.
TAPER LOCKING ASSEMBLIES
Used on rotors and gears to simplify removal and refitting.
TIMING PORT PLATE
Located at the drive end, it permits easy entry to the taper locking assembly (eliminating the need to remove the gearcase cover), allowing pump to be re-timed in the event of a blockage within the pump casing. No more worries about oil drain-down!
Heavy Duty AGMA quality timing gear accessible for timing without having to drain the gear case.
Different Sealing Options, Cartridge Type Front Pullout with Shaft Protection Sleeves.
LABYRINTH BEARING ISOLATOR
Stainless steel construction eliminates ingress of liquid into the gearbox. Double-lip oil seal retains oil; grease nipple allows grease input to act as barrier within the labyrinth. Functions in static or running state.
Lower Oil Chamber for lower bearings and continued timing gears lubrication
Upper Oil Chamber to ensure lubrication of the upper bearings at low speed
OPTIONAL REAR WEARPLATES
Upper and lower plates to protect casing. Retained via a series of externally-sealed fasteners.
FRONT-LOADING SEAL AREA
Allows the hardened shaft sleeves or mechanical seals to be removed cartridge style through the front of the pump—without removal of the casing.
Hinged Front Cover
Heavy-Duty Rotary Lobe Pumps for All Applications
LOBELINE™ is designed for superior pumping capabilities in a wide range of industrial applications. Choose from 8 models, each available in 12 sizes to suit a variety of operating conditions. Both bare pump and complete pump and drive packages are available. With interchangeable seal arrangements and a selection of wet end metallurgies and designs for your specific application, LOBELINE offers the perfect engineered pumping solution to meet your needs.
- Capacities to 3600 GPM (818 m3/hr)
- Pressures to 150 PSIG (10 bar)
- Temperatures to 400° F (204° C)
- Fluid Viscosities up to 1,000,000 cps
Lobeline™ is a Positive Displacement Pump with the following
operational
features:
Pump Runs Dry
Non-contacting pumping elements allow periodic use without fluid. Excellent for fluid transfers from tank to tank. Requires no flow indication equipment as used on Screw (Progressive Cavity) pumps that would seize and malfunction if run dry.
Low Shear Action
Smooth tri-lobe geometry provides gentle rolling action enabling shear sensitive fluids to be pumped with minimal damage.
Reversible Flow
Ability to utilize pump in both directions excellent for purging lines or changing pumping system requirements enabling greater process control.
Gas/Air Entrained Fluids
Lobe design can easily handle fluid containing gas/air. Centrifugal pumps are low on efficiency and are prone to losing prime.
Pump Jamming
With LOBELINE simply remove the front cover plate to inspect or clear the pump blockage. Many other pump types such as Screw (Progressive Cavity), Flexible Member (Hose), Plunger, Diaphragm if jammed require substantial disassembly to simply inspect or clear blockages.
Solids Handling
Ability to handle incompressible solids up to 31⁄2″ (90mm) suspended within the fluid.
Metering/Controlled Flow
Provides smooth predictable flow with minimal pulsation or surging when faced with varying pressures. Does not require pulsation dampeners like Plunger, Diaphragm type pumps.
Power Consumption Expense
Lobe pumps require less power due to the non-contacting design. Screw (Progressive Cavity) due to their design require higher start up and running horsepower. Centrifugal pumps require increased power on viscosities greater than 300-500 cps.
Pump Installation Space Problem
Lobe pumps require substantially less floor space than traditional Screw (Progressive Cavity) and Plunger type pumps.
We’re just a message or call away!
Feel free to reach out to us! Our team is here to provide expert guidance and answer any questions you may have about our high-quality rotary pumps.